Solar inverter system, auto ower-On/Off function, real-time monitoring, test & intelligent startup
Delivery term:The date of payment from buyers deliver within days-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Beijing
-
Validity to:
Long-term effective
-
Last update:
2017-12-06 02:59
-
Browse the number:
86
+
Huntkey Enterprise Group
- Contactaixin:
Contactaixin:
eastups(Ms.)
- telephone:
-
Area:
Beijing
Address:Banxue Street, Bantian Village, Buji Town, Shenzhen, Guangdong, China (518112)
- Website:
+
Model Number: Off-grid solar inverter 3~8KW
Key Specifications/Special Features:
FeaturesIndependent MPPT control microprocessor systemIndependent inverter control microprocessor system featured with high-speed online stabilizationAdvanced SPWM technology, high-speed power MOSMPPT control using PWM technology enable to bear the maximum PV open-circuit voltageOperating mode selectable: PV priority or utility power priorityCharging current selectable according to configured batteryAC input with effective online synchronous stabilization technology
Auto-tracking mains phase to ensure that inverter output voltage has same phase with utility voltage, reducing transfer time and peak surge
No-load auto shutdown function (optional)
Automatic frequency selection
Auto Power-On/Off function; real-time monitoring, test and intelligent startup / shutdown by RS232 or USB interface communicating with PC; remote monitoring by optional SNMP networks
MODEL | GF3000 | GF4000 | GF3000 | GF5000 | GF6000 | GF8000 |
Rated power | 3 KW | 4 KW | 3 KW | 5 KW | 6 KW | 8 KW |
Battery voltage | 96 Vdc | 192 Vdc | ||||
Operating mode | PV priority / AC priority | |||||
PV INPUT | ||||||
Input voltage range | 96 Vdc ~ 200 Vdc | 192 Vdc ~ 400 Vdc | ||||
Max. charging current | 10 ~ 60 A selectable | 10 ~ 40 A selectable | 10 ~ 60 A selectable | |||
Optimum operating voltage (Vmp) | 120 ~ 142 Vdc | 240 ~ 284 Vdc | ||||
Max. PV power (Pmax) | 5760 W | 7680 W | 11520 W | |||
Max. conversion efficiency | 98% | |||||
AC INPUT | ||||||
Input voltage | 165 ~ 275 Vac | |||||
Input frequency | 40 ~ 70 Hz (overloacking: auto transfer to DC power supply) | |||||
Waveform | Sinusoidal | |||||
Output voltage | 220 Vac ± 5% | |||||
Input power factor | ≥ 0.8 | |||||
Max. efficiency | 88% (online mode) | |||||
Max. charging current | 8 A | 12 A | ||||
Short circuit | Current-limiting, transfer to bypass; air circuit-breaker | |||||
INVERTER OUTPUT | ||||||
Output voltage | 220 Vac ± 5% | |||||
Output frequency | 50 Hz / 60 Hz ± 1% (auto-sense) | |||||
Output power factor | 1 | |||||
Waveform distortion | ≤ 5% (linear load) | |||||
Transfer time (PV – AC) | 0 ms | |||||
Max. efficiency | 92% | |||||
Short circuit | Current-limiting, transfer to bypass or system auto shutdown | |||||
ALARMS | ||||||
Utility power abnormal | 4 s per beep , auto mute in 40 s | |||||
Low battery | 0.2 s per beep | |||||
Overload | 1 s per beep | |||||
COMMUNICATIONS | ||||||
Communication interface | RS232, USB, RS485, SNMP (optional) | |||||
Dry contacts | PV fault, low battery, overload, bypass, inverter fault, generator ON / OFF | |||||
OTHERS | ||||||
Overload protections | 110% for 255 s; 125% for 60 s; 150% for 10 s | |||||
Wiring | Terminal blocks | |||||
EMI | EN62040-2:2006; EN61000-3-2:2006; EN61000-3-3:2008 | |||||
IP rating | IP20 | |||||
Ambient temperature | 0℃ ~ 40℃ | |||||
Relative humidity | 10% ~ 90% (non-condensing) | |||||
Noise | ≤ 50 dB | |||||
Operating altitude | 2000 m (derating 1% for each additional 100 m) | |||||
Dimensions (W × D × H) (mm) | 560 × 265 × 725 | |||||
Packaged dimensions (W × D × H) (mm) | 662 × 360 × 905 | |||||
Net weight (kg) | 76 | 80 | 60 | 67 | 69 | 85 |
Gross weight (kg) | 85 | 89 | 69 | 76 | 78 | 94 |
Shipping Information:
- FOB Port: Shenzhen
- Lead Time: 15 - 25 days
Main Export Markets:
- Asia
- Australasia
- Central/South America
- Eastern Europe
- Mid East/Africa
- North America
- Western Europe